Sensor+ Portable Pack (SP+ Series) CEM+ to CEM3 Retrofit ManualRevision BCopyright © Electronic Theatre Controls, Inc.All Rights reserved.Product info
8 CEM3 Sensor+ Portable Pack Retrofit ManualRemove the CEM+ BackplaneStep 1: Remove the lid retaining bolts using a wrench (may be 7/16” or 3/8” depen
2 The Retrofit 9Replace Phase A Bus BarA slightly modified Phase A bus bar is included in the upgrade kit. This new bus bar allows for greater clearan
10 CEM3 Sensor+ Portable Pack Retrofit ManualAttach New Power HarnessThe upgrade kit contains a power wire harness adapter that will connect to the ol
2 The Retrofit 11c: Secure the ring connector to the backplane using the 6-32 x 1/4” screw with lock washer (ETC part # HW213) from the upgrade kit. I
12 CEM3 Sensor+ Portable Pack Retrofit ManualBackplane SettingsUpgrade kit backplanes ship from the factory with all DIP switches in the off (down) po
2 The Retrofit 13Install New Pack Lid and Reassemble PackA new pack lid with the appropriate beacon board and Sensor3 sticker is included in the kitSt
14 CEM3 Sensor+ Portable Pack Retrofit ManualStep 12: Place the pack side rails back into their original locations and secure them with the 5/32” alle
ETC permits the reproduction of materials in this manual only for non-commercial purposes. All other rights are reserved by ETC.ETC®, and Sensor® are
Corporate Headquarters 3031 Pleasant View Road, P.O. Box 620979, Middleton, Wisconsin 53562-0979 USA Tel +608 831 4116 Fax +608 836 1736London,
Introduction 1IntroductionThis manual is intended to guide ETC Service Technicians through the process of upgrading existing Sensor®+ portable packs t
2 CEM3 Sensor+ Portable Pack Retrofit ManualOther Retrofit KitsThis retrofit kit is for upgrading a Sensor+ CEM+ portable pack to a CEM3 portable pack
Introduction 3Overview of this ManualReference this manual throughout the retrofit procedure.• Preparation, page 7- emptying the rack and removing the
4 CEM3 Sensor+ Portable Pack Retrofit Manual
1 Unpack and Organize 5Section 1Unpack and OrganizeThe table below lists the parts and components needed to retrofit a Sensor+ portable pack (SP12+ or
6 CEM3 Sensor+ Portable Pack Retrofit ManualRequired Tools#1 Phillips screwdriver#2 Phillips screwdriver3/8” socket7/16” socket5/32” Allen wrench7/16”
2 The Retrofit 7Section 2The RetrofitPreparationStep 1: Use the Sensor+ Connect web interface to download and save the current configuration out of th